These external subscriber telephone cables are installed as telecommunication connection cable for connecting the telephone extension to the telephone exchange or central offices and as well as for industrial plants. These subscriber connecting cables are suitable for laying in under ground, in cable ducts and cable conduits - and also for indoor-laying. Both sides of PE-copolymere coated aluminium type (L), which is spliced with the outer PE-sheath ensures a barrier against water vapour and diagonally water-proof. Black coloured PE-sheath is UV-resistant. The Polyethelene material (PE 2Y) is halogen-free.
These external subscriber telephone cables are installed as telecommunication connection cable for connecting the telephone extension to the telephone exchange or central offices and as well as for industrial plants. These subscriber connecting cables are suitable for laying in under ground, in cable ducts and cable conduits - and also for indoor-laying. Both sides of PE-copolymere coated aluminium type (L), which is spliced with the outer PE-sheath ensures a barrier against water vapour and diagonally water-proof. Black coloured PE-sheath is UV-resistant. The Polyethelene material (PE 2Y) is halogen-free.
UV-resistant
halogen-free
Bare copper conductor, single-wire
Core insulation of PE (2Y)
Core identification of quads marked with black rings
4 cores twisted to a star quad
5 star quads stranded to sub units,
each 5 or 10 sub units stranded to main
units and the sub or main units stranded to cable core
Core wrapping with several plastic tapes
Outer sheath, as laminated sheath (L)2Y,
PE-coated aluminium tape spliced with PE (2Y) sheath
Sheath colour: black
Sheath marking continuously with telephone-receiver, meter marking in white colour
Temperature range
flexible -20°C to +50°C
fixed installation to +70°C
Loop resistance at 20°C
0,6 mm = max. 130 Ohm/km
0,8 mm = max. 73,2 Ohm/km
Operating peak voltage max. 225 V
(not for heavy current installation purposes)
Test voltage
core/core U eff. 500 V
core/screen U eff. 2000 V
Insulation resistance: min. 5 GOhm x km
Line attenuation
of side circuits at 800 Hz
0,6 mm = 1,04 dB/km
0,8 mm = 0,78 dB/km
Impedance of side circuites at 800 Hz
0,6 mm = 720 Ohm
0,8 mm = 520 Ohm
Minimum bending radius: 10x cable Ø
Radiation resistance: up to 80x106 cJ/kg