Widely used in automatic CNC machining centers and low capacitance feedback, encoders, rotary transformers, speed sensors, signals and systems and other drag chain system signal and control use. EMC compliant copper wire shielding to prevent electromagnetic interference.
Conductor material: bare copper wire
Conductor class: According to DIN VDE 0295 Class 6 conductor or IEC 60228 Class 6 conductor
Insulation :PVC-J-105-003(2105-LF)(PP/HDPE optional)
Core identifier :< 0.5mm ²; 5 core and below using color separation, in line with n.DIN 47100, more than 5 core multi-core cable using core wire color separation, white ink dot distinction; ≥0.5mm²; Color separation is used for 5-core and below, including yellow/green wire, in line with n.DIN 47100, multi-core cables with more than 5-core black core wire, white ink numbered distinction (customized according to special requirements)
Cabling: core twisted pair or layer twisted, more detailed structure, please refer to the product technical parameters
Shielding layer: tinned copper wire braid shielding shielding density ≥80%
Outer sheath: DQPVC-H-90-003(9039-LF)
Jacket color: black (RAL 9005): Grey (RAL 7001): Green (RAL 6018)
Rated voltage :30V; 300V
Test voltage :500V, 1500V
Small bending radius: fixed 4 x d
Small bending radius: Move 7.5 x d
Moving speed: Self-supporting: max.8 m/s, coasting: max.5 m/s
Conductor length: Self-supporting/coasting max.400 m
Acceleration :max.100 m/s²
Bending cycle :<35 times /Min, life >12 million times
Temperature rating is fixed :-50°C/+80°C
Temperature rating shift :-40°C/+80C
Smoldering grade: According to IEC 60332-1-2,cable flame test, FT1, FT2
Certification :CE; UL/CUL If UL certification and halogen-free requirements are required, please note them separately