Typical application areas
For heavy duty applications with torsion movements
Almost unlimited resistance to oil, also with bio-oils
Indoor and outdoor applications, UV resistant
Especially for robots and 3D movements, handling, lead screw drives
•Conform to UL&CUL standard UL758,CSA C22.2 No. 210
•Conform to 2014/35/EU-Guideline (''Low voltage Directive'') CE
•We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Min. bend radius, e-chain® (factor) |
10.0 x d |
|
Min. bend radius, e-chain® |
3.7 inch (95.0 mm) |
|
Min. bend radius, flexible (factor) |
8.0 x d |
|
Min. bend radius, flexible |
3.0 inch (76.0 mm) |
|
Min. bend radius, fixed (factor) |
5.0 x d |
|
Min. bend radius, fixed |
1.9 inch (47.5 mm) |
|
Temperature, e-chain® min. |
-13 °F (-25 °C) |
|
Temperature, e-chain® max. |
176 °F (80 °C) |
|
Temperature, flexible |
-40 °F to +176 °F (-20 °C to +80 °C) |
|
Temperature, fixed |
-58 °F to 176 °F (-50 °C to 80 °C) |
|
v max. twisted |
180 °/m |
|
a max.twisted |
60 °/s² |
|
Length of travel |
Robots and motions in 3D area, Class 1 |
|
|
Torsion |
± 180°, with 1 m cable length |
Conductor |
Very finely stranded special cores of particularly high-flex design made of bare copper wires. |
|
|
Conductor insulation |
Mechanically high-quality TPE mixture
|
|
Overall shield |
Torsion-resistant tinned braided copper shield. Coverage approx.80 % optical.
|
|
Element shield |
Extremely torsion-resistant tinned braided copper shield. Coverage approx. 85 % optical |
Unshielded |
No |
|
|
Outer jacket |
Low-adhesion, halogen-free, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN EN 50363-10-2).
|
|
Conductor identification
|
According to measuring system specification
|
Jacket color |
Steel blue (similar to RAL 5011) |