Typical application areas
For flexing applications
With influence of oil
Indoor and outdoor applications without direct solar radiation
Especially for unsupported travels
Machining units/machine tools, low temperature applications
•Conform to UL&CUL standard UL758,CSA C22.2 No. 210
•Conform to 2014/35/EU-Guideline (''Low voltage Directive'') CE
•We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Min. bend radius, e-chain® (factor) |
15 x d |
|
Min. bend radius, e-chain® |
4.7 inch (120.0 mm) |
|
Min. bend radius, flexible (factor) |
12 x d |
|
Min. bend radius, flexible |
3.8 inch (96mm) |
|
Min. bend radius, fixed (factor) |
8 x d |
|
Min. bend radius, fixed |
2.5 inch (64mm) |
|
Temperature, e-chain® min. |
-4 °F (-20 °C) |
|
Temperature, e-chain® max. |
176 °F (80 °C) |
|
Temperature, flexible |
-40 °F to +176 °F (-20 °C to +80 °C) |
|
Temperature, fixed |
-58°F to +176°F (-50°C to +80°C) |
|
v max. unsupproted |
16 ft/s (5 m/s) |
|
v max. gliding |
10 ft/s (3 m/s) |
|
a max., twisted |
65.6 ft/s² (20 m/s²) |
|
Length of travel |
Travels up to 33 ft (10 m) |
Conductor |
Conductor consisting of bare copper wires (according to DIN EN 60228) |
|
Conductor insulation |
Mechanically high-quality TPE mixture (According to bus specification) |
|
Overall shield |
Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. |
|
Unshielded |
No |
|
Outer jacket |
Low-adhesion, halogen-free, highly abrasion-resistant mixture on the basis of iguPUR, adapted to suit the requirements in energy chains® |
|
Jacket color |
Yellow-green (similar to RAL 6018) |