Typical application areas
For medium duty use
Light oil influence
Preferably indoor applications, but also outdoor ones at temperatures > 41.0 °F (5 °C)
Unsupported travel distances and up to 32.81 ft (10 m) for gliding applications
Wood/stone processing, packaging industry, supply systems, handling, adjusting equipment
•Conform to UL&CUL standard UL758,CSA C22.2 No. 210
•Conform to 2014/35/EU-Guideline (''Low voltage Directive'') CE
•We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Min. bend radius, e-chain® (factor) |
10.0 x d |
|
Min. bend radius, e-chain® |
3.7 inch (95.0 mm) |
|
Min. bend radius, flexible (factor) |
8 x d |
|
Min. bend radius, flexible |
3.0 inch (76.0 mm) |
|
Min. bend radius, fixed (factor) |
5 x d |
|
Min. bend radius, fixed |
1.9 inch (47.5 mm) |
|
Temperature, e-chain® min. |
41 °F (5 °C) |
|
Temperature, e-chain® max. |
158 °F (70 °C) |
|
Temperature, flexible |
+23 °F to +158 °F (-5 °C to +70 °C) |
|
Temperature, fixed |
+5°F to +158°F (-15°C to +70°C)(following DIN EN 50305) |
|
v max. unsupported |
33 ft/s (10 m/s) |
|
v max. gliding |
7 ft/s (2 m/s) |
|
a max. |
164.0 ft/s² (50 m/s²) |
|
Length of travel |
Travels up to 33 ft (10 m) |
Conductor |
Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (according to DIN EN 60228) |
|
Conductor insulation |
Mechanically high-quality, especially low-capacitance TPE mixture |
|
Overall shield |
Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. |
|
Unshielded |
No |
|
Outer jacket |
Low-adhesion, halogen-free, highly abrasion-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN EN 50363-10-2). |
|
|
Inner jacket |
PVC mixture suited to the requirements in e-chains®
|
Jacket color |
Pastel orange (similar to RAL 2003) |