•conform to RoHS •conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
•We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Product structure
| Conductor material: | Bare copper strand |
|---|---|
| Conductor class: | Super fine wires acc.to VDE 0295 cl. 6 pt. 4 resp. IEC60228 cl. 6 pt. 4 |
| Core insulation: | PELON®2 |
| Core identification: | Coloured acc. to DIN 47100 |
| Overall stranding: | Cores stranded in layers with filler |
| Shield3: | Copper braid tinned, coverage approx. 85% ± 5% |
| Outer sheath: | PVC |
| Sheath colour: | Grey RAL 7001 |
| Outer diameter: | 4,8 +/- 0,2 mm |
| Rated voltage: | Acc. to VDE: 300/300V; acc. to UL: 300 V |
| Testing voltage: | Core/core: 1.500 V; core/shield: 500 V |
| Conductor resistance: | At +20 °C acc. to DIN VDE 0295 cl.6 resp. IEC60228 cl.6 |
| Insulation resistance: | At +20 °C ≥ 500 MΩ x km |
| Current-carrying-capacity: | Acc. to DIN VDE |
| Capacity: | Core/core: approx. 65 pF/m |
| Inductivity: | Approx. 0,6 mH/km |
| Min. bending radius fixed: | 5 x d |
| Min. bending radius moved: | 7,5 x d < 10 m TL; 10 x d ≥ 10 m TL |
| Operat. temp. fixed min/max: | -40 °C / +80 °C |
| Operat. temp. moved min/max: | -5 °C / +80 °C |
| Burning behavior: | Flame-retardant acc. to IEC 60332-1-2, FT1 |
| Resistant to oil: | Acc. to DIN EN 60811-2-1 (only mineral oil) |
| Approvals: | UL/CSA - cURus 300V, 80°C |
| Speed: | Self-supporting: max. 5 m/s, gliding: max. 2,5 m/s |
| Acceleration: | Max. 10 m/s² |