Typical application areas
CF14US-02-04-02-UV is good for direct sunlight
For extremely heavy duty applications
Suitable for indoor/outdoor applications without direct sunlight
Especially for unsupported and gliding travel up to 164 ft (50m)
For application lengths > 164 ft (50m) use igus® P/N CFBUS-045
Storage and retrieval units for high-bay warehouses, machine tools, quick handling,cleanroom, semiconductor insertion, indoor cranes, low temperature applications
•Conform to UL&CUL standard UL758,CSA C22.2 No. 210
•Conform to 2014/35/EU-Guideline (''Low voltage Directive'') CE
•We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Min. bend radius, e-chain® (factor) |
12.5 x d |
|
Min. bend radius, e-chain® |
3.7 inch (95 mm) |
|
Min. bend radius, flexible (factor) |
10.0 x d |
|
Min. bend radius, flexible |
3 inch (76 mm) |
|
Min. bend radius, fixed (factor) |
7.5 x d |
|
Min. bend radius, fixed |
2.2 inch (57 mm) |
|
Temperature, e-chain® min. |
-4 °F (-20 °C) |
|
Temperature, e-chain® max. |
158 °F (70 °C) |
|
Temperature, flexible |
-40 °F to +158 °F (-40 °C to +70 °C) (following DIN EN 60811-504) |
|
Temperature, fixed |
-58 °F to 158 °F (-45 °C to 70 °C) (following DIN EN 50305) |
|
a max., twisted |
328.1 ft/s² (100 m/s²) |
|
Length of travel |
Travels up to 164 ft (50 m) Travels up to 164 ft (50 m) |
Conductor |
Conductor consisting of bare copper wires (according to DIN EN 60228) |
|
Conductor insulation |
Foam polyethylene |
|
Overall shield |
Tinned copper, 90% optical coverage |
|
Unshielded |
No |
|
Outer jacket |
Low adhesion PUR blend adapted to the requirements of the energy chain |
|
Inner jacket |
TPE mixture suited to the requirements in e-chains®
|
|
Jacket color |
Violet |