TKD CABLE
  • Alternative TKD ZKSi ignition Cable, HZLSi high voltage ignition Cable, SiL SiL neon Cable

Alternative TKD ZKSi ignition Cable, HZLSi high voltage ignition Cable, SiL SiL neon Cable

ZKSI as silicone ignition cable, HZLSI as silicone high voltage ignition cable and SIL as silicone neon fluorescent tube cable, for application in various surrounding temperatures, in lamp and luminair industry, e.g. flood light, industrial luminair, electric heating industry, in thermo and process technology, in refrigeration and air-conditioning technology. Suitable for use in dry, humid and wet rooms and outdoor use, no laying underground.

EMAILEMAIL:info@aein-cable.com

Product introduction
  • 01 Product application ZKSI as silicone ignition cable, HZLSI as silicone high voltage ignition cable and SIL as silicone neon fluorescent tube cable, for application in various surrounding temperatures, in lamp and luminair industry, e.g. flood light, industrial luminair, electric heating industry, in thermo and process technology, in refrigeration and air-conditioning technology. Suitable for use in dry, humid and wet rooms and outdoor use, no laying underground.
  • 02 Product characteristicslargely resistant to acids, bases and specified types of oil approved for conductor temperature class "H" up to +180 °C no flame conduction in case of fire, insulation integrity and low smoke densitysilicone is resistant to ozone, oxygen, sea water and weather-proofed
  • 03 Technical certification

    conform to RoHS conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE

     •We are pleased to produce special versions, other dimensions, core and jacket colours on request.

Product structure
Conductor material: Copper strand tinned
Conductor class: Acc. to DIN VDE 0295 class 5 resp. IEC 60228 cl. 5                                                                                                             
Core insulation: Silicone
Core identification: ZKSI: blue, HZLSI: redbrown, SIL: yellow
Shield3: ZKSI: glass-silk braid
Outer sheath: ZKSI: silicone
Sheath colour: ZKSI: blue
Rated voltage: Uo: ZKSI: 16 kV; SIL: 3,5 kV-4 kV-7,5 kV
Testing voltage: Uo: ZKSI 20 kV; HZLSI 15 kV on 5mm Ø, 20 kV on 7mm Ø; SIL 10 kV
Conductor resistance: At +20 °C acc. to DIN VDE 0295 class 5 resp. IEC 60228 cl. 5
Current-carrying-capacity: Acc. to DIN VDE, see Technical Guidelines
Min. bending radius fixed: 4 x d
Min. bending radius moved: 7,5 x d
Operat. temp. fixed min/max: -60 °C / +180 °C; short-time: +200 °C
Temp. at conductor: +180 °C
Halogen free: Halogen-free acc. to VDE 0472 part 813 and IEC 60754-1
Burning behavior: Self-extinguishing and flame-retardant VDE 0482-332-2-1 (IEC 60332-1)