TKD CABLE
  • Alternative TKD  5288 SK-C-PUR UL/CSA SERVO 0,6/1kV Cable

Alternative TKD 5288 SK-C-PUR UL/CSA SERVO 0,6/1kV Cable

shielded, low capacity power cable with control cores for temperature sensors or brake for EMC-compatible connecting between drives and frequency converter for normal requirements in drag chain applications, moving drive systems, in the field of robotic technology and manufacturing plants. Suitable for use in dry and humid rooms.

EMAILEMAIL:info@aein-cable.com

Product introduction
  • 01 Product application shielded, low capacity power cable with control cores for temperature sensors or brake for EMC-compatible connecting between drives and frequency converter for normal requirements in drag chain applications, moving drive systems, in the field of robotic technology and manufacturing plants. Suitable for use in dry and humid rooms.
  • 02 Product characteristicslow adhesion and low abrasion flame-retardant acc. to IEC 60332-1-2 halogen- and CFC-free acc. to DIN VDE 0472-815, IEC 60754-1resistant to oil acc. to DIN EN 60811-404, VDE 0473-811-404 and EN 50363-10-2
    largely resistant to grease, coolant fluids and lubricants
    UV-resistant, silicone-free conform to DESINA, UL/CSA approved
  • 03 Technical certification

    conform to RoHS conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE

     •We are pleased to produce special versions, other dimensions, core and jacket colours on request.

Product structure
Conductor material: Bare copper strand
Conductor class: Acc. to DIN VDE 0295 cl. 6 resp. IEC 60228 cl. 6
Core insulation: PUR
Core identification: Supply cores: BK with WH print U/L1/C/L+; V/L2; W/L3/D/L- and GNYE; control cores: 1-pair, BK and WH; 2-pair: BK with WH print 5, 6, 7, 8; triple: bk with wh numerals 1. 2, 3
Shield: Control pairs resp. triple with tinned copper shield
Overall stranding: All cores and elements stranded together with high flexible fillers
Shield3: Copper braid tinned, opt. coverage appr. 85 %
Outer sheath: PUR, halogen-free, flame retardant
Sheath colour: Orange, RAL 2003
Rated voltage: Uo/U 600/1.000 V; UL & CSA: 1.000 V
Testing voltage: 4 kV
Conductor resistance: At +20 °C acc. to DIN VDE 0295 cl. 6/IEC 60228 cl. 6
Insulation resistance: At +20 °C ≥ 20 GΩ x km
Min. bending radius fixed: 4 x d - after installation
Min. bending radius moved: 7,5 x d (≤ 16 mm²) / 10 x d (≥ 25 mm²)
Operat. temp. fixed min/max: -50 °C / +80 °C
Operat. temp. moved min/max: -40 °C / +80 °C
Burning behavior: Self-extinguishing and flame-retardant acc. to IEC 60332-1-2
Torsion: 30°/m
Approvals: UL/CSA - cURus 1.000 V, 80 °C