TKD CABLE
  • Alternative TKD NSGAFÖU Special Rubber Core

Alternative TKD NSGAFÖU Special Rubber Core

For fixed laying in rail vehicles and buses as well as in dry rooms, in pipes and closed installation canals. Suitable for connecting of flexible units.

EMAILEMAIL:info@aein-cable.com

Product introduction
  • 01 Product application For fixed laying in rail vehicles and buses as well as in dry rooms, in pipes and closed installation canals. Suitable for connecting of flexible units.
  • 02 Product characteristicscables with 3 kV operating voltage in low voltage facilities up to 1.000 V are classified as short circuit and earth leakage protected connection
  • 03 Technical certification

    conform to RoHS conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE

     •We are pleased to produce special versions, other dimensions, core and jacket colours on request.

Product structure
Conductor material: Tinned copper strands
Conductor class: Acc. to DIN VDE 0295 class 5 resp. IEC 60228 cl. 5
Core insulation: Rubber compound
Outer sheath: Special rubber-compound
Sheath colour: Black
Rated voltage: Uo/U: 1,8/3 kV
Testing voltage: 6 kV
Current-carrying-capacity: Reference value acc. to VDE see table on the right side.For divergent environmental conditions see conversion factors, technical guideline p. 16.076 and following
Min. bending radius fixed: 5 x d
Min. bending radius moved: 5 x d
Operat. temp. fixed min/max: -40 °C / +80 °C
Operat. temp. moved min/max: -25 °C / +80 °C
Temp. at conductor: +90 °C
Burning behavior: Self-extinguishing and flame-retardant acc. to IEC 60332-1
Resistant to oil: Acc. to EN 60811-404
Standard: Acc. to DIN VDE 0250 part 602