Data transmission, control and connection cables are used primarily for analog and digital signal transmission of process control facilities in measurement and control technology. Suitable for fixed laying and mobile applications, no clear cable path and no tensile stress. Suitable for dry and wet indoor use, with oil resistance, wear resistance, acid and alkali resistance, water resistance, UV resistance features.
Conductor material: Bare copper wire
Conductor grade: In accordance with IEC 60228 cl. 5standard
Insulation:PVC
Identification of core wire:< 0,5 mm²:5 Core and below the use of color separation, in line withn. DIN 47100.5Multi-core cable above core adopts core separation , white ink dot distinguish; ≥ 0,5 mm²: 5 Core and below use color separation, containing yellow/Green line, matchn. DIN 47100.5Multi-core cable above the core adopts black core wire, white ink numbered to distinguish (If there are special requirements to customize)
Wring: Wring in layers
Shielding layer: Tinned copper braid, coverage approx70%
Outer sheath: TPU-H-90-004
Jacket color: Black RAL9005;grey RAL 7001
Rated voltage:0.5 And below 300/300V;0.5 above 300/500V
Test voltage:0.5 And below 1500V;0.5 above 2000V
Conductor resistance: In accordance with DIN VDE 0812
Insulation resistance: minimum 500 GΩ x km
Capacitance: core/core about 120 nF/km; core/Masking contract 160 nF/km
Minimum bending radius:12mm The following Ø 5 x d; 20mmThe following Ø 7,5 x d; > 20mm Ø 10 x d
Minimum bending radius:12mm The followingØ 10 x d; 20mmThe followingØ 15 x d; > 20mm Ø 20 x d
Fixed temperature grade:-15 ℃ / +80 °C
Temperature class shift:-5 ℃/ +80 °C
Standard:DIN VDE 0812
Flame retardant class:Self-extinguishing and flame retardant meet IEC 60332-1-2 standard
Product identification:Aein bei ke SHANGHAI AEIN WIRE & CABLE CO.,LTD Model number specification voltage CE Meter scale