CE certified cable
  • (N)SHOEU Flexible rubber cables 0,6/1 kV

(N)SHOEU Flexible rubber cables 0,6/1 kV

Rubber-sheated flexible cables for open-cast mining, suitable for laying alongside conveyor belts (also for shiftable units) and on material handling equipment, even when the cable is moved continuously, e.g. in cable suspension fittings and as connection between upper and lower cars. The cables are also suitable for connection of submersible pump units.

EMAILEMAIL:info@aein-cable.com

Product introduction
  • 01 Product application


    Rubber-sheated flexible cables for open-cast mining, suitable for laying alongside conveyor belts (also for shiftable units) and on material handling equipment, even when the cable is moved continuously, e.g. in cable suspension fittings and as connection between upper and lower cars. The  cables are also suitable for connection of submersible pump units.


  • 02 Product characteristics


    Reaction to fire

    Resistance to oil

    Weather resistance Unrestricted use outdoors and indoors, resistant to ozone and moisture

    Water resistance



  • 03 Technical certification • Conform to RoHSWe are pleased to produce special versions, other dimensions, core and jacket colours on request.
Product structure

Conductor Electrolytic copper, not tinned, finely stranded

Insulation:EPR, Compound

Core identification Light gray with black digits

Core arrangement Three main conductors laid-up together with the protective-earth conductor, from 50 mm² with

protective-earth conductor split into three in the outer interstices

Screen In case of concentric screen (KON types only): closed layer of copper wire spinning over core assembly

Inner sheath Basic material: EPR, Compound type: Special compound

Outer sheath Basic material: Chlorinated rubber, Compound type: Special compound, Color: Black

Rated voltage

Uo/U=450/750 V (Control cables); Uo/U=0.6/1 kV (Power cables)

Max. permissible operating voltage AC 0.7/1.2 kV

Max. permissible operating voltage DC 0.9/1.8 kV

AC test voltage - main cores 3 kV (5 Min.)

AC test voltage - control cores 2 kV

Max. permissible temperature at conductor 90 °C

Max. short circuit temperature of the conductor 250 °C

Max. permissible water temperature 40 °C (At higher water temperatures, a shortened cable service life is to be expected)

Ambient temperature for fixed installation min -40 °C ; max +80 °C

Ambient temperature in fully flexible operation min -25 °C ; max +60 °C 