Conductor material: Bare copper or tinned copper
Conductor Class: Conform to UL758 Standard, ASTM B3 or ASTM B33 standard. VDE 0295 5 Conductor pt.4 or. IEC60228 5 Conductor pt.4
Core insulation:PVC,XLPE,TPE optional
Core Identification: According to VDE 0293-308 most 5 Root colored thread, from 6 Root black thread with white numbers, with or without yellow/Green hinge
Stranding: Cores resp. bundles parallel side by side
Shielding: Tinned copper wire braided shielding, shielding density>70%
Outer sheath: Flame retardant PUR
Jacket color: Black RAL9005, gray RAL7001 yellow RAL1023(Optional)
Rated voltage:600V,1000V
Test voltage:600V: 2AWG 2000V; 1-4/0 2500V; 250kcmil-500kcmil 3000V ;501kcmil-1000kcmil 3500V
1000V:3000V
Min. bending radius fixed:7.5x d
Min. bending radius moved:10x d
Operat. temp. fixed min/max:-40 °C / +80 °C
Operat. temp. moved min/max:-30 °C / +80 °C
Burning behavior: Self-extinguishing and flame retardant meet FT2
Oil resistance:UL1581:IRM 902; Conform to DIN EN 60811-2-1
Approvals: UL&CUL:CE
Product identification: Aein bei ke E503807 ® AWM Model number specification temperature voltage ® AWM Ⅰ/Ⅱ A/B specification temperature voltage FT2 SHANGHAI AEIN Model number specification voltage CE