UL758 Standard Cable
  • UL20233 Twist Pair Shielded UL Certified Cable

UL20233 Twist Pair Shielded UL Certified Cable

UL& CUL certified data transmission cables, control and connection cables are mainly used to transmit analog and digital signals in the process control facilities of measurement and control technology, to achieve lossless data and signal transmission, suitable for high demand towed chains and mobile drive systems. External connection cables for electronic devices. With oil resistance, wear resistance, acid and alkali resistance, waterproof, UV resistance.

EMAILEMAIL:momo.tao@aein-cable.com

Product introduction
  • 01 Product application UL& CUL certified data transmission cables, control and connection cables are mainly used to transmit analog and digital signals in the process control facilities of measurement and control technology, to achieve lossless data and signal transmission, suitable for high demand towed chains and mobile drive systems. External connection cables for electronic devices. With oil resistance, wear resistance, acid and alkali resistance, waterproof, UV resistance.
  • 02 Product characteristics • Low adhesion
    • UV resistance
    • Conform to RoHS
    • Flame retardant coincidence CSA C22.2 No.2556-15 FT2
    • Oil resistance acc. to UL1581:IRM 902. DIN EN 60811-1-2
    • Recommend for EMC application
    • Highly resistant to acids, alkalis and certain types of oils
  • 03 Technical certification • Conform to UL&CUL Standard, UL758, CSA C22.2 No. 210
    • Conform to 2014/35/EU-Guideline (''Low voltage Directive'') CE
    •  We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Product structure

Conductor material: bare copper or tinned copper

Conductor class: acc. to UL758 Standard, ASTM B3 or ASTM B33 Standard, DIN VDE 0295 5, or. IEC 60228 5

Core insulation: PVC, HDPE, TPE optional

Core wire identification: <20AWG: 5 cores and below are distinguished by color separation, acc. to Din 47100, multi-core cables above 5 cores are distinguished by core wire color separation, and white ink is used for distinction; ≥20AWG: 5 cores and below are distinguished by color separation, including yellow/ Green ground wire, acc.to Din 47100, multi-core cables with more than 5 cores use black core wires, and white ink numbers are used to distinguish them. (customized upon request if there are special requirements)

Stranding: twisted into a pair; layered of pairs

Sheath: Flame retardant TPU

Jacket color: gray RAL7001 Or black RAL9005

Rated voltage: acc. UL:300V; CE:300/300V

Testing voltage: Core wire/Core wire: 2.0kV

Conductor resistance: UL1581 ASTM class C

Insulation resistance: PVC:+20 °C ≥ 20 MΩ x km; HDPE:+20 °C ≥ 500 MΩ x km

Minimum bending radius fixed:4x d

Minimum bending radius moved: 7.5x d

Speed and Self-supporting: max. 10 m/s, glide: max. 5 m/s

Conductor length: max. 50 m

Acceleration: max. 20 m/s²

Bending cycle:<35 /Min; Life span>1200w

Operat. temp. fixed min/max: HDPE&TPE: -50 °C / +80 °C; PVC:-40 °C / +80 °C

Operat. temp. moved min/max: HDPE&TPE: -40 °C / +80 °C ; PVC-30 °C / +80 °C

Burning behavior: self - extinguishing and flame retardant; CSA C22.2 No.2556-15 FT2

Oil resistance: UL1581: IRM 902; acc. to DIN EN 60811-2-1

Certification:UL&CUL:UL1007,UL1185,UL1569,UL11076,UL10450,UL10586,UL10149,UL20233
           CE:LiYC11Y-TP,Li2YC11Y-TP,Li12YC11Y-TP  
If needed CE Certification or halogen-free requirements shall be indicated separately

Product identification:Aein bei ke E503807   AWM  Model number  specification temperature  voltage c   AWM Ⅰ/Ⅱ A/B specification temperature  voltage  FT2  SHANGHAI  AEIN   Meter scale

Product parameter
Related products