UL&CUL certified data transmission cables, control and connection cables are mainly used to transmit analog and digital signals in process control facilities in measurement and control technology to achieve lossless data and signal transmission. Suitable for fixed installation and mobile applications without defined cable paths and without tensile stress. Suitable for use in dry and humid indoors. External interconnections of electronic equipment or internal wiring of electronic equipment or appliances.The label could also read something like: "600 Volts Peak, Electronic Use Only"
•UL&CUL certified data transmission cables, control and connection cables are mainly used to transmit analog and digital signals in process control facilities in measurement and control technology to achieve lossless data and signal transmission. Suitable for fixed installation and mobile applications without defined cable paths and without tensile stress. Suitable for use in dry and humid indoors. External interconnections of electronic equipment or internal wiring of electronic equipment or appliances. The label could also read something like: "600 Volts Peak, Electronic Use Only"
• Conform to RoHS standard • Cold resistance • Soft
Conductor material: Bare copper or tin plating
Conductor resistance: In accordance with UL758 Standard, ASTM B3 or ASTM B33 Standard, DIN VDE 0295 5 Conductor or. IEC 60228 5 Conductor
Insulation PVC (automotive material).
Core identification:<20AWG: 5 cores and below are distinguished by color separation, acc. to Din 47100, multi-core cables above 5 cores are distinguished by core wire color separation, and white ink is used for distinction; ≥20AWG: 5 cores and below are distinguished by color separation, including yellow/ Green ground wire, acc.to Din 47100, multi-core cables with more than 5 cores use black core wires, and white ink numbers are used to distinguish them. (customized upon request if there are special requirements)
Stranding :The core wire is twisted into a pair; Layering of pairs
Shielding layer:Tinned copper braid; Coverage is about 70%
Sheath: PVC
Jacket color: Gray RAL7001 Or black RAL9005
Rated voltage:300V
Test voltage: Core/Core:2.0 kV;
Conductor resistance:UL1581 ASTM class C
Insulation resistance:+20 °C ≥ 20 MΩ x km
Min. bending radius fixed:7.5x d
Min. bending radius moved:15x d
Operat. temp. fixed min/max:-40 °C / +105 °C
Operat. temp. moved min/max:-30 °C / +105 °C
Burning behavior: Self-extinguishing and flame retardant UL1581 VW-1;CSA C22.2 No.2556-15 FT1,FT2;IEC 60332-1-2 standard
Approvals: UL&CUL:UL1569,UL2517
CE: FLRYY If needed CECertification requirements should be specified separately
Marking: Aein bei ke E503807 ® AWM Model number specification temperature voltage ® AWM Ⅰ/Ⅱ A/B specification temperature voltage FT2 SHANGHAI AEIN Meter scale