Conductor material: Copper stranded wire
Conductor Class: In accordance with DIN VDE 0295 5 Class, refer to IEC 60228 5 class
Core insulation:EP
Core identification: Preferred color: black, white, red, yellow green (green), orange, from 6 Root black RAL9005Line, with white numbers, with or without yellow/green
Stranding: Core stranding and filling
Outer sheath:CPE
Jacket color: Black RAL9005(Optional)
Rated voltage:300V
Test voltage:18AWG-11AWG 2000V; 10AWG 3000V
Min. bending radius fixed:7.5x d
Min. bending radius moved:10x d
Operat. temp. fixed min/max: --40 °C / +105 °C -40 °C / +90 °C -40 °C / +75 °C -40 °C / +60 °C
Operat. temp. moved min/max: --40 °C / +105 °C -40 °C / +90 °C -40 °C / +75 °C -40 °C / +60 °C
Burning behavior: Self-extinguishing and flame retardant Conform to IEC60332-1-2 FT1 VW-1
Oil resistance: Meet EN 60811-2-1
Approvals: UL/CE
Product identification: Aein bei ke E503806 (UL) Model number *×**AWG(**mm²) temperature voltage c(UL) Model number *×**mm²(**AWG) temperature voltage FT2 SHANGHAI AEIN Model number specification voltage CE