UL&UL&CUL certification is applicable for indoor/outdoor use. Portable tools, equipment, small motors and related machinery, appliances and devices exposed to oil, solvents, flames, moisture and other electrical equipment that requires flexibility and durability. Suitable for applications up to 600 V and temperatures ranging from -40°C to +105° C.
It has excellent resistance to oil, acid, chemicals, water, oxygen, extreme temperatures, cutting, tearing and wear.
S= Service line (600 volts)
O= Oil-resistant outer sheath
W= the weather resistance/water resistance specified by CSA
Conductor material: Copper stranded wire
Conductor grade: Complies with DIN VDE 0295 Class 5 and refers to IEC 60228 Class 5
Core wire insulation :EP
Core wire identification: Preferred colors: black, white, red, yellow-green (green), orange, from 6 black RAL 9005 wires, with white numbers, with or without yellow/green
Shielding density :≥85%
Outer sheath :CPE
Outer sheath color: Black RAL9005(optional)
Rated voltage :600V
Test voltage :≤13AWG 2000V:12AWG-9AWG 3000V:8AWG-2AWG 4000V
Fixed minimum bending radius :7.5 x d
Small bending radius movement :10 x d
Working temperature fixed small/large values: to 40 ° C / + 105 ° C to 40 ° C / + 90 ° C to 40 ° C / + 75 ° C to 40 ° C / + 60 ° C
Temperature rating mobile - 40 ° C/small/large value + 105 ° C to 40 ° C / + 90 ° C to 40 ° C / + 75 ° C to
40 ° C / + 60 ° C
Flame retardant grade: Self-extinguishing and flame retardant comply with IEC60332-1-2 FT1 VW-1
Oil resistance: Complies with EN 60811-2-1
Certification :UL/CE
Product Identification: Aein bei ke E503806(UL) model *x**AWG (*mm²) Temperature Voltage ((UL) Model *x**mm²(**AWG) Temperature Voltage FT2 SHANGHAI AEIN Model Specification Voltage CE