CE certified cable
  • YSLYCY EU CE Certified Cable Double Sheathed Oil resistant Cable

YSLYCY EU CE Certified Cable Double Sheathed Oil resistant Cable

Power, control and connection cables in power installations are used in environments where anti-electromagnetic interference is required for data and signal transmission and may be used in fixed laying or other mobile situations. The cable is suitable for dry, wet and humid indoor use.

EMAILEMAIL:info@aein-cable.com

Product introduction
  • 01 Product application Power, control and connection cables in power installations are used in environments where anti-electromagnetic interference is required for data and signal transmission and may be used in fixed laying or other mobile situations. Cable suitable for drying﹑damp﹑Wet indoor use.
  • 02 Product characteristics Cable resistant to acid and alkali﹑Oil resistance
    The cable structure with inner sheath can enhance the protection of the cable
    Shielded cables must meet the requirements EMC Demand.
    Good chemical resistance

  • 03 Technical certification • Conform to RoHS standard• Conform to 2014/35/EU-Guideline (''Low voltage Directive'') CE
    • We are pleased to produce special versions, other dimensions, core and jacket colours on request.

Structural parameter

Conductor material: bare copper wire

Conductor class: In accordance with IEC60228 cl.5standard 

Core insulation:PVC-J-80-005

Core identification   < 0,5 mm²:5Core and below the use of color separation, in line withn. DIN 47100.5Multi-core cable above core adopts core separation , white ink dot distinguish; ≥ 0,5 mm²: 5Core and below use color separation, containing yellow/Green line, matchn. DIN 47100.5Multi-core cable above the core adopts black core wire, white ink numbered to distinguish(If there are special requirements to customize)

Hinge:Layered stranding

Inner sheath PVC

Shield :Tinned copper braid with coverage of approx 80 %

Outer sheathing material:DQ PVC-H-80-005

Color of outer sheath: Transparent

Rated voltage:300/500 V

Test voltage:2 kV

Conductor resistance Conform to IEC 60228 cl. 5standard

Insulation resistance minimum 20 MΩ x km

Min. bending radius fixed 6 x d

Min. bending radius moved 20x d

Operat. temp. fixed min/max: -40 °C / +80 °C

Operat. temp. moved min/max: -5 °C / +80 °C

Maximum temperature + 70 °C Operating temperature; +150 °C Short-circuit temperature

Standard:Conform to EN 50525-2-51| 0,6/1 kV-type: Insulation thickness execution 1KV Standard thickness

Product identification      Aein bei ke   SHANGHAI  AEIN  WIRE & CABLE  CO.,LTD   Model number  specification voltage   CE   Meter scale