shielded, low capacity hybrid cable for applications with fixed or conditionally flexible installation in electrical drive technology, as a connection cable servo controler and motor, in assembly and insertion machines, especially for the wet area of transfer lines or machine tools.
•conform to RoHS •conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
•We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Conductor material: | Bare copper strand |
---|---|
Conductor class: | Acc. to IEC 60228 cl. 6 col. 4 |
Core insulation: | PELON®2 |
Core identification: | BK with WH print U/L1/C/L+;V/L2;W/L3/D/L- & 1core GNYE; signalpair: WH,BU, controlpair (optional): BK with WH numerals 5+6 |
Shield: | Signal pair/control pair: each pair shielded with tinned copper braid, optic. cover. appr. 85% |
Overall stranding: | Cores & elements stranded together |
Shield3: | Copper braid tinded, cover. appr. 85% |
Outer sheath: | PUR |
Sheath colour: | Orange, RAL 2003 |
Rated voltage: | Power- & control cores: IEC: 0,6/1kV; UL/CSA: 1kV; signal pair: max. 300V |
Testing voltage: | Power- & control cores: 4 kV, signal pair: 1 kV |
Conductor resistance: | At +20 °C acc. to IEC 60228 cl. 6 |
Insulation resistance: | At +20 °C ≥ 20 MΩ x km |
Current-carrying-capacity: | Acc. to DIN VDE |
Characteristic impedance: | Signal pair: approx. 100 Ohm |
Transfer rate: | 9.375 Mbaud until 100 m |
Min. bending radius fixed: | 5 x d |
Min. bending radius moved: | 7,5 x d < 10m TL | 10 x d ≥ 10m TL |
Operat. temp. fixed min/max: | -50°C / +80°C |
Operat. temp. moved min/max: | -40 °C / +80 °C |
Burning behavior: | Flame-retardant acc. to IEC 60332-1-2, FT1, VW-1 |
Approvals: | UL/CSA - cURus 1.000 V, 80°C |
Speed: | Self-supporting: max. 5 m/s |
Acceleration: | Max. 10 m/s² |