Power, control and connecting cable for drive systems with frequency converter technology, for fixed laying and casually movement without tensile stress and without defined cable routing. Suitable for use in dry, humid and wet rooms. Outdoor use, but no laying underground.

EMAILEMAIL:info@aein-cable.com

Product introduction
  • 01 Product application Power, control and connecting cable for drive systems with frequency converter technology, for fixed laying and casually movement without tensile stress and without defined cable routing. Suitable for use in dry, humid and wet rooms. Outdoor use, but no laying underground.
  • 02 Product characteristicslargely resistant to acids, bases and specified types of oil low operating capacity, low coupling resistance with UV-resistant, halogen-free outer sheath enables trouble-free operation of frequency converters through optimum EMC compliant shielding
  • 03 Technical certification

    conform to RoHS conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE

    • We are pleased to produce special versions, other dimensions, core and jacket colours on request.

Product structure
Conductor material: Bare copper strand
Conductor class: Acc. to IEC 60228 cl. 5
Core insulation: XLPE
Core identification: Acc. to DIN VDE 0293-308 coloured cores with GNYE
Stranding: Stranded in layers
Shield: Alu-lamin. polyester foil, metal side outside, cover. 100% under copper braid tinned
Outer sheath: Halogen-free compound
Sheath colour: Black, RAL 9005
Rated voltage: Uo/U 0,6/1 kV - highest permissible operating voltage Single phase and three-phase: 700/1200 V, DC operation: 900/1800 V
Testing voltage: 4 kV
Conductor resistance: Acc. to IEC 60228 cl. 5
Insulation resistance: Min. 200 MΩ x km
Capacity: Look at the table on the right side
Min. bending radius fixed: ≤ 12mm Ø: 5 x d; ≤ 20mm Ø: 7,5 x d; > 20mm Ø: 10 x d
Min. bending radius moved: ≤ 12mm Ø: 10 x d; ≤ 20mm Ø: 15 x d; > 20mm Ø: 20 x d
Operat. temp. fixed min/max: -40 °C / +80 °C
Operat. temp. moved min/max: -15 °C / +70 °C
Temp. at conductor: + 90 °C in operation; +250 °C in case of short-circuit
Halogen free: Halogen-free acc. to IEC 60754-1
Burning behavior: Self-extinguishing & flame-retardant acc.to IEC 60332-1-2