For fixed laying in rail vehicles and buses as well as in dry rooms, in pipes and closed installation canals. Suitable for connecting of flexible units.
EMAIL:info@aein-cable.com
Product introduction
01Product applicationFor fixed laying in rail vehicles and buses as well as in dry rooms, in pipes and closed installation canals. Suitable for connecting of flexible units.
02Product characteristics•cables with 3 kV operating voltage in low voltage facilities up to 1.000 V are classified as short circuit and earth leakage protected connection•halogen-free •UV resistant
03Technical certification
•conform to RoHS •conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
•We are pleased to produce special versions, other dimensions,
core and jacket colours on request.
Product structure
Conductor material:
Tinned copper strand
Conductor class:
Acc. to DIN VDE 0295 class 5 resp. IEC 60228 cl. 5
Core insulation:
Rubber compound
Outer sheath:
Halogen-free rubber compound
Sheath colour:
Black
Rated voltage:
Uo/U: 1,8/3 kV
Testing voltage:
6 kV
Current-carrying-capacity:
Reference value acc. to VDE see table on the right side.For divergent environmental conditions see conversion factors, technical guideline p. 16.076 and following
Min. bending radius fixed:
6 x d
Min. bending radius moved:
10 x d
Operat. temp. fixed min/max:
-40 °C / +80 °C
Operat. temp. moved min/max:
-25 °C / +80 °C
Temp. at conductor:
+90 °C
Halogen free:
Acc. to DIN VDE 0472 part 813
Smoke density:
Acc. to IEC 61034
Burning behavior:
Self-extinguishing and flame-retardant acc. to IEC 60332-1-2