as shielded, low capacity feedback, encoder, resolver, spedo sensor, signal & system cables for EMC compatible connecting in maschine and plant enginering, as well as in drive and control technology, for high electrical and mechanical requirements in drag chain applications, moving drive systems and in the field of robotic technology.
•conform to RoHS •conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
•We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Conductor material: | Bare copper strand |
---|---|
Conductor class: | Acc. to DIN VDE0295 cl. 6 resp. IEC 60228 cl. 6 |
Core insulation: | PELON®2 |
Core identification: | Acc. to system specification (on request) |
Stranding: | Cores stranded to pairs or layers |
Shield: | Elements: C: copper braid tinned resp. D: spiral copper shield tinned, opt. coverage appr. 85% |
Element sheath material: | TPE - black (if mentioned 12Y) |
Overall stranding: | Elements strand. together |
Shield3: | Copper braid tinned, opt. coverage appr. 85% |
Outer sheath: | PUR |
Sheath colour: | GN - RAL 6018 (DESINA), OR - RAL 2003 or BK - RAL 9005 |
Rated voltage: | 300 V, no high-voltage purpose |
Testing voltage: | 500 V |
Conductor resistance: | Acc. to DIN VDE 0295 cl. 6 resp. IEC 60228 cl. 6 |
Insulation resistance: | Min. 20 MΩ x km |
Min. bending radius fixed: | 4 x d |
Min. bending radius moved: | 7,5 x d < 10 m TL | 10 x d ≥ 10 m TL |
Operat. temp. fixed min/max: | - 50 °C / +80 °C |
Operat. temp. moved min/max: | - 40 °C / +80 °C |
Halogen free: | Yes |
Burning behavior: | Flame-retardent acc. to IEC 60332-1-2, FT1 |
Torsion: | 30°/m |
Standard: | UL/CSA: cURus 300V, 80°C |
Speed: | Self-supporting - max. 5 m/s |
Acceleration: | Max. 50 m/s² |